Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Acta Ophthalmol ; 99(5): e679-e685, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33210819

RESUMO

PURPOSE: To examine feasibility of phase-contrast magnetic resonance imaging (PCMRI) and to assess blood flow rate in the ophthalmic artery (OA) in patients with normal tension glaucoma (NTG) compared with healthy controls. METHODS: Sixteen patients with treated NTG and 16 age- and sex-matched healthy controls underwent PCMRI using a 3-Tesla scanner and ophthalmological examinations. OA blood flow rate was measured using a 2D PCMRI sequence with a spatial resolution of 0.35 mm2 . RESULTS: The blood flow rate in the NTG group was 9.6 ± 3.9 ml/min [mean ± SD] compared with 11.9 ± 4.8 ml/min in the control group. Resistance Index (RI) and Pulsatility Index (PI) were 0.73 ± 0.08 and 1.36 ± 0.29, respectively, in the NTG group and 0.68 ± 0.13 and 1.22 ± 0.40, respectively, in the healthy group. The mean visual field index (VFI) was 46% ± 25 for the worse NTG eyes. The measured differences observed between the NTG group and the control group in blood flow rate (p = 0.12), RI (p = 0.18) and PI (p = 0.27) were non-significant. CONCLUSIONS: This case-control study, using PCMRI, showed a slight, but non-significant, reduction in OA blood flow rate in the NTG patients compared with the healthy controls. These results indicate that blood flow may be of importance in the pathogenesis of NTG. Considering that only a limited portion of the total OA blood flow supplies the ocular system and the large inter-individual differences, a larger study or more advanced PCMRI technique might give the answer.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Intraocular/fisiologia , Glaucoma de Baixa Tensão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Artéria Oftálmica/diagnóstico por imagem , Idoso , Estudos de Viabilidade , Feminino , Humanos , Glaucoma de Baixa Tensão/diagnóstico , Masculino , Artéria Oftálmica/fisiopatologia , Estudos Prospectivos , Curva ROC , Ultrassonografia Doppler em Cores
2.
Invest Ophthalmol Vis Sci ; 61(12): 17, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33074299

RESUMO

Purpose: To investigate if decrease of IOP affects the volumetric blood flow rate in the ophthalmic artery (OA) in patients with previously untreated ocular hypertension. Methods: Subjects with untreated ocular hypertension (n = 30; mean age 67 ± 8 years; 14 females) underwent ophthalmologic examination and a 3-Tesla magnetic resonance imaging investigation. The magnetic resonance imaging included three-dimensional high-resolution phase-contrast magnetic resonance imaging to measure the OA blood flow rate. The subjects received latanoprost once daily in the eye with higher pressure, the untreated eye served as control. The same measurements were repeated approximately 1 week later. Results: The mean OA blood flow rate before and after treatment was 12.4 ± 4.4 and 12.4 ± 4.6 mL/min in the treated eye (mean ± SD; P = 0.92) and 13.5 ± 5.2 and 13.4 ± 4.1 mL/min in the control eye (P = 0.92). There was no significant difference between the treated and control eye regarding blood flow rate before (P = 0.13) or after treatment (P = 0.18), or change in blood flow rate after treatment (0.1 ± 3.1 vs. -0.1 ± 4.0 mL/min, P = 0.84). Latanoprost decreased the IOP by 7.2 ± 3.1 mm Hg in the treated eye (P < 0.01). Conclusions: The results indicate that a significant lowering of IOP does not affect the blood flow rate of the OA in ocular hypertension subjects. The ability to maintain blood supply to the eye independent of the IOP could be a protective mechanism in preserving vision in subjects with ocular hypertension.


Assuntos
Pressão Intraocular/fisiologia , Hipertensão Ocular/fisiopatologia , Artéria Oftálmica/fisiopatologia , Idoso , Anti-Hipertensivos/uso terapêutico , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Feminino , Humanos , Latanoprosta/uso terapêutico , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/tratamento farmacológico , Estudos Prospectivos , Fluxo Sanguíneo Regional/fisiologia , Tonometria Ocular
3.
Appl Opt ; 56(35): 9787-9792, 2017 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-29240126

RESUMO

A numerical 3D ray tracing model was used to evaluate the long-term visual effects of two regimens of corneal crosslinking (CXL) treatment of 48 patients with the corneal degeneration keratoconus. The 3D ray tracing analyses were based on corneal elevation data measured by Scheimpflug photography. Twenty-two patients were treated with standard CXL applied uniformly across the corneal surface, whereas 26 patients underwent a customized, refined treatment only at local zones on the cornea (photorefractive intrastromal CXL; PiXL). Spot diagrams, spot root-mean-square (RMS) values, and Strehl ratios were evaluated for the patients prior to and 1, 3, 6, and 12 months after treatment. It was found that the group of patients treated with PiXL, on average, tended to attain a long-term improvement of the corneal optical performance, whereas only minor changes of the optical parameters were found for group treated with standard CXL. Our results confirmed that standard CXL treatment stabilizes the corneal optical quality over time, and thus halts the progression of the corneal degeneration. In addition to stabilization, the results showed that a significantly higher proportion of subjects treated with PiXL improved in RMS, 3, 6, and 12 months after treatment, compared to with CXL (p<0.05). This finding indicates that the PiXL treatment might improve optical quality over time.

4.
Appl Opt ; 55(16): 4378-82, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27411190

RESUMO

Based on numerical 3D ray tracing, we propose a new procedure to optimize personalized intra-ocular lenses (IOLs). The 3D ray tracing was based on measured corneal elevation data from patients who suffered from advanced keratoconus. A mathematical shape description of the posterior IOL surface, by means of a tensor product cubic Hermite spline, was implemented. The optimized lenses provide significantly reduced aberrations. Our results include a trade-off study that suggests that it is possible to considerably reduce the aberrations with only minor perturbations of an ideal spherical lens. The proposed procedure can be applied for correction of aberrations of any optical system by modifying a single surface.


Assuntos
Lentes Intraoculares , Erros de Refração/terapia , Humanos , Ceratocone/terapia , Implante de Lente Intraocular
5.
Appl Opt ; 55(3): 507-14, 2016 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-26835925

RESUMO

We propose a numerical three-dimensional (3D) ray-tracing model for the analysis of advanced corneal refractive errors. The 3D modeling was based on measured corneal elevation data by means of Scheimpflug photography. A mathematical description of the measured corneal surfaces from a keratoconus (KC) patient was used for the 3D ray tracing, based on Snell's law of refraction. A model of a commercial intraocular lens (IOL) was included in the analysis. By modifying the posterior IOL surface, it was shown that the imaging quality could be significantly improved. The RMS values were reduced by approximately 50% close to the retina, both for on- and off-axis geometries. The 3D ray-tracing model can constitute a basis for simulation of customized IOLs that are able to correct the advanced, irregular refractive errors in KC.


Assuntos
Imageamento Tridimensional , Ceratocone/complicações , Modelos Teóricos , Erros de Refração/complicações , Córnea/patologia , Humanos , Ceratocone/patologia , Fenômenos Ópticos , Fotografação , Erros de Refração/patologia
6.
JAMA Ophthalmol ; 133(11): 1254-60, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26312777

RESUMO

IMPORTANCE: We describe and evaluate a complementary method to indirectly quantify the treatment effect of corneal cross-linking (CXL). Additional methods to indirectly quantify the treatment effect of CXL are needed. OBJECTIVE: To assess the spatial distribution and the time course of the increased corneal densitometry (corneal light backscatter) seen after CXL with riboflavin and UV-A irradiation. DESIGN, SETTING, AND PARTICIPANTS: Open-label randomized clinical trial of 43 patients (60 eyes) who were 18 to 28 years of age and had progressive keratoconus and a plan to be treated with CXL at Umeå University Hospital, Umeå, Sweden. The patients were randomized to receive conventional CXL (n = 30) using the Dresden protocol or CXL with mechanical compression of the cornea using a flat rigid contact lens sutured to the cornea during the treatment (CRXL) (n = 30). All participants were followed up during a 6-month period from October 13, 2009, through May 31, 2012. INTERVENTIONS: Corneal cross-linking according to the Dresden protocol or CRXL. MAIN OUTCOMES AND MEASURES: Change in corneal densitometry after CXL and CRXL for keratoconus. RESULTS: Of the original 60 eyes included, 4 had incomplete data. A densitometry increase was seen after both treatments that was deeper and more pronounced in the CXL group (difference between the groups at 1 month in the center layer, zone 0-2 mm, 5.02 grayscale units [GSU], 95% CI, 2.92-7.12 GSU; P < .001). This increase diminished with time but was still noticeable at 6 months (difference between the groups at 6 months in the center layer, zone 0-2 mm, 3.47 GSU; 95% CI, 1.72-5.23 GSU; P < .001) and was proportional to the reduction in corneal steepness (R = -0.45 and -0.56 for CXL and CRXL, respectively). CONCLUSIONS AND RELEVANCE: The degree of corneal light backscatter relates to the reduction in corneal steepness after cross-linking and may become a relevant complement to other methods in evaluating the cross-linking effect, for example, when comparing different treatment regimens. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT02425150.


Assuntos
Córnea/fisiologia , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas , Ceratocone/tratamento farmacológico , Fotoquimioterapia/métodos , Espalhamento de Radiação , Adolescente , Adulto , Colágeno/metabolismo , Densitometria , Feminino , Humanos , Ceratocone/metabolismo , Luz , Masculino , Fármacos Fotossensibilizantes/uso terapêutico , Riboflavina/uso terapêutico , Resultado do Tratamento , Raios Ultravioleta , Adulto Jovem
7.
JAMA Ophthalmol ; 132(12): 1426-32, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25171564

RESUMO

IMPORTANCE: A reliable tool for quantification of the biomechanical status of the cornea in conjunction with corneal collagen crosslinking (CXL) treatment is needed. OBJECTIVE: To quantify the biomechanical effects of CXL in vivo. DESIGN, SETTING, AND PARTICIPANTS: A prospective, open, case-control study was conducted at the Department of Ophthalmology, Umeå University, Umeå, Sweden. Participants included 28 patients (29 eyes) aged 18 to 28 years with progressive keratoconus and corresponding age- and sex-matched healthy individuals serving as controls. All participants were monitored during a 6-month period between October 13, 2009, and November 5, 2012. MAIN OUTCOMES AND MEASURES: Corneal hysteresis after CXL for keratoconus. RESULTS: A difference in corneal hysteresis between the control group and the patients with keratoconus was found at baseline, both with an applanation resonance tonometer (ART) and an ocular response analyzer (ORA), at mean (SD) values of -1.09 (1.92) mm Hg (99% CI, -2.26 to 0.07; P = .01) and -2.67 (2.55) mm Hg (99% CI, -4.05 to -1.32; P < .001), respectively. Increased corneal hysteresis was demonstrated with an ART 1 and 6 months after CXL, at 1.2 (2.4) mm Hg (99% CI,-0.1 to 2.5; P = .02) and 1.1 (2.7) mm Hg (99% CI, -0.3 to 2.6; P = .04), respectively, but not with ORA. A decrease in corneal thickness was seen 1 and 6 months after treatment (-24 [26] µm, P < .001; and -11 [21] µm, P = .01, respectively), and a corneal flattening of -0.6 (0.7) diopters was seen at 6 months (P < .001). No significant change in intraocular pressure was identified in patients with keratoconus with any method, except for an increase at 1 month with Goldmann applanation tonometry (P = .005). CONCLUSIONS AND RELEVANCE: To our knowledge ART is the first in vivo method able to assess the increased corneal hysteresis after CXL treatment. Given the large-scale use of CXL in modern keratoconus treatment, a tool with this capacity has a great potential value. Refinement of the ART method of measuring and quantifying corneal biomechanical properties will be a subject of further studies.


Assuntos
Colágeno/metabolismo , Córnea/fisiopatologia , Substância Própria/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Elasticidade/fisiologia , Ceratocone/tratamento farmacológico , Tonometria Ocular/instrumentação , Adolescente , Adulto , Fenômenos Biomecânicos , Estudos de Casos e Controles , Feminino , Humanos , Pressão Intraocular , Ceratocone/metabolismo , Ceratocone/fisiopatologia , Masculino , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta , Adulto Jovem
8.
Graefes Arch Clin Exp Ophthalmol ; 252(10): 1607-10, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25030238

RESUMO

PURPOSE: To evaluate the effect of intracameral air on intraocular pressure (IOP) measurements using Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) in an in-vitro porcine eye model. METHODS: IOP was measured on thirteen freshly enucleated eyes at three reference pressures: 20, 30, and 40 mmHg. Six measurements/method were performed in a standardized order with GAT and ART respectively. Air was injected intracamerally in the same manner as during Descemet's stripping endothelial keratoplasty (DSEK) and Descemet's membrane endothelial keratoplasty (DMEK), and the measurements were repeated. RESULTS: Measured IOP increased significantly for both tonometry methods after air injection: 0.7 ± 2.1 mmHg for GAT and 10.6 ± 4.9 mmHg for ART. This difference was significant at each reference pressure for ART but not for GAT. CONCLUSIONS: Although slightly affected, this study suggests that we can trust GAT IOP-measurements in eyes with intracameral air, such as after DSEK/DMEK operations. Ultrasound-based methods such as ART should not be used.


Assuntos
Ar , Câmara Anterior/fisiologia , Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Animais , Humanos , Modelos Animais , Reprodutibilidade dos Testes , Suínos
9.
Acta Ophthalmol ; 92(7): 644-9, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24628999

RESUMO

PURPOSE: To compare refractive changes after corneal crosslinking with and without mechanical compression of the cornea. METHODS: In a prospective, open, randomized case-control study conducted at the Department of Ophthalmology, Umeå University Hospital, Sweden, sixty eyes of 43 patients with progressive keratoconus aged 18-28 years planned for corneal crosslinking and corresponding age- and sex-matched control subjects were included. The patients were randomized to conventional corneal crosslinking (CXL; n = 30) or corneal crosslinking with mechanical compression using a flat rigid contact lens sutured to the cornea during treatment (CRXL; n = 30). Subjective refraction and ETDRS best spectacle-corrected visual acuity (BSCVA), axial length measurement, keratometry and pachymetry were performed before and 1 and 6 months after treatment. RESULTS: The keratoconus patients had poorer BSCVA, higher refractive astigmatism and higher keratometry readings than the control subjects at baseline (p < 0.01). In the CXL group, BSCVA increased from 0.19 ± 0.26 to 0.14 ± 0.18 logMar (p = 0.03), and the spherical equivalent improved from -1.9 ± 2.8 D to -1.4 ± 2.4 D (p = 0.03). Maximum keratometry readings decreased after CXL from 53.1 ± 4.9 D to 52.6 ± 5.2 D (p = 0.02), and the axial length decreased in the CXL group, likely due to post-treatment corneal thinning (p = 0.03). In the CRXL group, all the above variables were unaltered (p > 0.05). CONCLUSION: At 6 months, the refractive results from CRXL did not surpass those of conventional CXL treatment. Rather, some variables indicated a slightly inferior effect. Possibly, stronger crosslinking would be necessary to stabilize the cornea in the flattened configuration achieved by the rigid contact lens.


Assuntos
Substância Própria/metabolismo , Reagentes de Ligações Cruzadas/uso terapêutico , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Refração Ocular/fisiologia , Estresse Mecânico , Acuidade Visual/fisiologia , Adolescente , Adulto , Comprimento Axial do Olho/patologia , Estudos de Casos e Controles , Colágeno/metabolismo , Paquimetria Corneana , Feminino , Humanos , Ceratocone/metabolismo , Masculino , Estudos Prospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta , Adulto Jovem
10.
Acta Ophthalmol ; 92(2): 111-5, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23387522

RESUMO

PURPOSE: To investigate the effects of repeated measurements of intraocular pressure (IOP) using Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) to identify mechanisms contributing to the expected IOP reduction. METHODS: A prospective, single-centre study with six healthy volunteers. Consecutive repeated series (six measurements/serie/method) were made alternately on both eyes for 1 hr with oxybuprocaine/fluorescein in the right eye and tetracaine in the left. The left eye was Pentacam(®) photographed before and repeatedly for 20 min after the IOP measurements. On a separate occasion, the same volunteers received the same amount of anaesthetic drops for 1 hr but without repeated IOP measurements. RESULTS: A significant IOP reduction occurred with both ART and GAT in the oxybuprocaine-treated eye, -4.4 mmHg and -3.8 mmHg, respectively and with ART in the tetracaine eye, -2.1 mmHg. There was a significant difference in IOP reduction between the oxybuprocaine and tetracaine eyes with ART. There was a significant drop in anterior chamber volume (ACV) immediately after the IOP measurements, -12.6 µl that returned to pretrial level after 2 min. After 1 hr of receiving anaesthetic eye drops (without IOP measurements), the IOP decreased significantly in the oxybuprocaine eye for both ART and GAT, -3.1 and -1.7 mmHg, respectively, but not in the tetracaine eye (p = 0.72). CONCLUSION: The IOP reduction cannot be explained solely by aqueous humor being pressed out of the anterior chamber. While significant IOP reduction occurred with both tetracaine and oxybuprocaine after repeated mechanical applanation, the IOP reduction was significantly greater with oxybuprocaine.


Assuntos
Anestésicos Locais/administração & dosagem , Pressão Intraocular/efeitos dos fármacos , Procaína/análogos & derivados , Tetracaína/administração & dosagem , Tonometria Ocular/instrumentação , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Procaína/administração & dosagem , Estudos Prospectivos
11.
Invest Ophthalmol Vis Sci ; 54(4): 2738-45, 2013 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-23518769

RESUMO

PURPOSE: Recent development of magnetic resonance imaging (MRI) offers new possibilities to assess ocular blood flow. This prospective study evaluates the feasibility of phase-contrast MRI (PCMRI) to measure flow rate in the ophthalmic artery (OA) and establish reference values in healthy young (HY) and elderly (HE) subjects. METHODS: Fifty HY subjects (28 females, 21-30 years of age) and 44 HE (23 females, 64-80 years of age) were scanned on a 3-Tesla MR system. The PCMRI sequence had a spatial resolution of 0.35 mm per pixel, with the measurement plan placed perpendicularly to the OA. Mean flow rate (Qmean), resistive index (RI), and arterial volume pulsatility of OA (ΔVmax) were measured from the flow rate curve. Accuracy of PCMRI measures was investigated using a vessel-phantom mimicking the diameter and the flow rate range of the human OA. RESULTS: Flow rate could be assessed in 97% of the OAs. Phantom investigations showed good agreement between the reference and PCMRI measurements with an error of <7%. No statistical difference was found in Qmean between HY and HE individuals (HY: mean ± SD = 10.37 ± 4.45 mL/min; HE: 10.81 ± 5.15 mL/min, P = 0.655). The mean of ΔVmax (HY: 18.70 ± 7.24 µL; HE: 26.27 ± 12.59 µL, P < 0.001) and RI (HY: 0.62 ± 0.08; HE: 0.67 ± 0.1, P = 0.012) were significantly different between HY and HE. CONCLUSIONS: This study demonstrated that the flow rate of OA can be quantified using PCMRI. There was an age difference in the pulsatility parameters; however, the mean flow rate appeared independent of age. The primary difference in flow curves between HE and HY was in the relaxation phase of the systolic peak.


Assuntos
Imageamento por Ressonância Magnética/métodos , Artéria Oftálmica/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Estudos de Viabilidade , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência , Adulto Jovem
12.
J Cataract Refract Surg ; 38(9): 1637-42, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22789494

RESUMO

PURPOSE: To evaluate intraocular pressure (IOP) measurements 24 months after laser-assisted subepithelial keratectomy (LASEK) with 3 tonometry methods-Goldmann applanation tonometry (GAT), Pascal dynamic contour tonometry (DCT), and applanation resonance tonometry (ART)-and to compare them with measurements taken preoperatively and 3 and 6 months postoperatively. SETTING: Department of Ophthalmology, Umeå University, Umeå, Sweden. DESIGN: Prospective randomized single-center. METHODS: One randomized eye per person from myopic healthy individuals who had LASEK was included. Visual acuity, central corneal thickness (CCT), corneal curvature, and IOP were measured at all time points. Six IOP measurements were performed per method, with a 5-minute lapse between methods. RESULTS: The study evaluated 38 eyes. Two years after LASEK, dynamic ART was the only method that did not measure significantly lower IOP than before LASEK (mean -0.2 mm Hg ± 1.6 [SD]). The greatest difference was with GAT (mean -1.9 ± 1.7 mm Hg) followed by static ART (mean -1.2 ± 1.6 mm Hg) and then DCT (mean -0.9 ± 1.3 mm Hg). All methods measured significantly lower IOP at 3 months and 6 months. CONCLUSIONS: Dynamic ART, which analyses IOP measurement during indentation, showed no significant difference in measured IOP after 24 months. The convex tip of the ART device and the continuous sampling of data during corneal indentation seem to be factors in why dynamic ART was less affected by corneal properties and therefore more suitable for IOP measurement in LASEK-treated eyes, although this must be confirmed in larger trials.


Assuntos
Córnea/cirurgia , Pressão Intraocular/fisiologia , Ceratectomia Subepitelial Assistida por Laser , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Adulto , Córnea/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Estudos Prospectivos , Fatores de Tempo , Tonometria Ocular/instrumentação , Acuidade Visual/fisiologia , Adulto Jovem
13.
Acta Ophthalmol ; 90(7): 677-82, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21323868

RESUMO

PURPOSE: In recent years, Applanation Resonance Tonometry (ART) has been suggested for intraocular pressure (IOP) measurements. The manual version of ART (ART(manual) ) has been further developed, and to improve usability, an automatic servo-controlled prototype (ART(servo) ) has been proposed. The aim of this study was to assess the limits of agreement (LoA) of ART(manual) and ART(servo) as compared with the reference method, Goldmann Applanation Tonometry (GAT). METHODS: This was a prospective single-centre study on 152 eyes from 77 subjects. It was designed according to International Standard Organization's (ISO) requirements for tonometers (ISO 2001). Intraocular pressure was measured six times/method in a standardized order. The ART technique has two available analysis procedures: a dynamic one that measures IOP during the indentation phase and a static one that causes a Goldmann-like measurement during two seconds of full applanation. The 95% LoA was defined as ±1.96 × standard deviation of difference against GAT. RESULTS: Mean IOP for GAT was 19.1 mmHg (range: 10-37 mmHg). The 95% LoA of ART(manual) was ±4.5 mmHg for both dynamic and static analyses. The 95% LoA of ART(servo) was ±5.7 mmHg for dynamic and ±4.9 mmHg for static analyses. CONCLUSIONS: This study confirms that the ART methodology is feasible. The further developed ART(manual) fulfilled the ISO standard with both the dynamic and the static analysis techniques. ART(servo) with static analysis was close to fulfilling the standard but failed to do so in the highest IOP range. ART(servo) has the potential to greatly improve usability if further development is completed.


Assuntos
Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
14.
J Glaucoma ; 21(4): 255-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-21654513

RESUMO

PURPOSE: To prospectively evaluate 3 tonometry methods--the gold standard, Goldmann applanation tonometry, a new method, Pascal dynamic contour tonometry (PDCT), and a method under development, applanation resonance tonometry (ART)--with respect to intraocular pressure (IOP) measurements before, 3 and 6 months after laser-assisted subepithelial keratectomy (LASEK). MATERIALS AND METHODS: One randomly assigned eye of each of 53 healthy individuals, who underwent LASEK surgery for myopia was studied. Visual acuity, central corneal thickness, corneal curvature, and IOP were measured at each visit. Six IOP measurements/methods with 5 minutes pause between methods were performed. RESULTS: All tonometry methods measured a significantly lower IOP after LASEK correction by a mean of -3.1 diopters. The IOP reduction was largest after 6 months for Goldmann applanation tonometry (-1.7 ± 1.8 mm Hg) followed by ARTstat (-1.2 ± 1.5 mm Hg), PDCT (-1.1 ± 1.6 mm Hg), and ARTdyn (-1.0 ± 1.5 mm Hg). The reduction of IOP did not differ significantly between different methods (P=0.11). There was a significant further reduction of measured IOP for PDCT between 3 and 6 months (-0.5 ± 1.0 mm Hg). Uncorrected visual acuity improved significantly between 3 and 6 months postoperatively from 1.32 ± 0.28 to 1.43 ± 0.27. CONCLUSIONS: All tonometry methods measured a significant, but low, reduction of IOP 3 and 6 months after LASEK. Further change in visual acuity and IOP measurements between 3 and 6 months suggest a still ongoing postoperative process.


Assuntos
Pressão Intraocular/fisiologia , Ceratectomia Subepitelial Assistida por Laser , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Tonometria Ocular/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miopia/fisiopatologia , Período Pós-Operatório , Período Pré-Operatório , Estudos Prospectivos , Acuidade Visual/fisiologia , Adulto Jovem
15.
J Telemed Telecare ; 15(8): 397-403, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19948706

RESUMO

We evaluated the feasibility and quality of uncomplicated hypertension care based on telemedicine in a rural area of northern Sweden. The intervention subjects were 91 consecutive patients with primary hypertension. For comparison, 182 age- and sex-matched patients with hypertension were randomly selected from a similar health centre. The telemedicine equipment consisted of a video link between the physician and the patients, supported by a system for accessing medical data via the Internet. During a 21-month study period, telemedicine was used in 270 (91%) of the 297 consultations in the intervention group. All health personnel involved in the telemedicine treatment rated the method as feasible. Both systolic and diastolic blood pressure improved in the two groups during the study period. In the intervention group, a higher proportion had their blood pressure within treatment goals (systolic blood pressure <140 mmHg, diastolic blood pressure <90 mmHg) both at baseline and at follow-up than in the comparison group. An adjusted multivariate model (adjustment for sex, age, time between visits, change in number of drugs between first and last visit, blood pressure at first visit) showed that the intervention group had a higher probability (OR 2.7, 95% CI 1.4-5.2) of reaching the target blood pressure levels than the reference group. Treatment of hypertension by means of telemedicine was quite feasible and at least as effective as face-to-face consultations with a physician.


Assuntos
Atitude , Medicina de Família e Comunidade , Hipertensão/terapia , Serviços de Saúde Rural , Telemedicina/normas , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/fisiologia , Estudos de Viabilidade , Feminino , Acessibilidade aos Serviços de Saúde , Humanos , Hipertensão/diagnóstico , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Médicos de Família/provisão & distribuição , Padrões de Prática em Enfermagem , Relações Profissional-Paciente , Suécia , Telemedicina/métodos , Telemedicina/estatística & dados numéricos , Comunicação por Videoconferência/normas , Comunicação por Videoconferência/estatística & dados numéricos
16.
Aviat Space Environ Med ; 79(9): 904-8, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18785360

RESUMO

INTRODUCTION: The ability of fingers to rapidly rewarm following cold exposure is a possible indicator of cold injury protection. We categorized the post-cooling hand-rewarming responses of men before and after participation in 15 mo of military training in a cold environment in northern Sweden to determine: 1) if the initial rewarming category was related to the occurrence of local cold injury during training; and 2) if cold training affected subsequent hand-rewarming responses. METHODS: Immersion of the dominant hand in 10 degrees C water for 10 min was performed pre-training on 77 men. Of those, 45 were available for successful post-training retests. Infrared thermography monitored the dorsal hand during 30 min of recovery. Rewarming was categorized as normal, moderate, or slow based on mean fingertip temperature at the end of 30 min of recovery (TFinger,30) and the percentage of time that fingertips were vasodilated (%VD). RESULTS: Cold injury occurrence during training was disproportionately higher in the slow rewarmers (four of the five injuries). Post-training, baseline fingertip temperatures and cold recovery variables increased significantly in moderate and slow rewarmers: TFinger30 increased from 21.9 +/- 4 to 30.4 +/- 6 degrees C (Moderate), and from 17.4 +/- 0 to 22.3 +/- 7 degrees C (Slow); %VD increased from 27.5 +/- 16 to 65.9 +/- 34% (Moderate), and from 0.7 +/- 2 to 31.7 +/- 44% (Slow). CONCLUSIONS: Results of the cold recovery test were related to the occurrence of local cold injury during long-term cold-weather training. Cold training itself improved baseline and cold recovery in moderate and slow rewarmers.


Assuntos
Adaptação Fisiológica , Temperatura Baixa/efeitos adversos , Exposição Ambiental/efeitos adversos , Medicina Militar , Militares , Aclimatação/fisiologia , Adulto , Regulação da Temperatura Corporal , Indicadores Básicos de Saúde , Humanos , Masculino , Manitoba , Projetos Piloto , Fatores de Tempo , Vasoconstrição/fisiologia
17.
Acta Ophthalmol ; 86(6): 614-21, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18093261

RESUMO

PURPOSE: To compare intraocular pressure (IOP) measurements by Pascal, ICare and Goldmann applanation tonometry (GAT), to evaluate the effects of central corneal thickness (CCT) and curvature on IOP measurement and to estimate the intra-observer variability. METHODS: A prospective, single-centre study of 150 eyes with a wide range of pressures. Six masked IOP measurements/method; corneal thickness and curvature were studied for each eye. GAT was the reference. RESULTS: IOPPascal and IOPICare correlated with IOPGAT (r = 0.91, 0.89). Mean ICare measurement exceeded GAT by 2 mmHg. Pascal measured higher than GAT at low IOPs and lower at high IOPs. For every 10 mmHg increase in IOP above 31 mmHg, Pascal measured 2 mmHg lower than GAT and vice versa. CCT was correlated significantly with IOPGAT (r = 0.23) and IOPICare (r = 0.43) but not with IOPPascal (P = 0.12). CCT was correlated with age. In a subgroup (>50 years), ICare and the difference between IOPGAT and IOPPascal were affected significantly by the CCT, whereas IOPGAT and IOPPascal were not. Corneal curvature was correlated significantly with IOPGAT (r = -0.27) and IOPPascal (r = -0.26) but not with IOPICare (P = 0.60). Intra-observer variability within each set of six measurements was approximately 2 mmHg, irrespective of method. CONCLUSION: This study showed a reasonable overall correlation and concordance between the IOP obtained with the three instruments. None of the methods were completely independent of the biomechanical properties of the cornea. ICare showed a significant dependency upon CCT, whereas GAT and Pascal showed a significant dependency on corneal curvature. All methods showed intra-observer variability, which leaves room for further improvement of methods.


Assuntos
Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Córnea/patologia , Feminino , Glaucoma/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Tonometria Ocular/normas
18.
J Glaucoma ; 16(1): 88-93, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17224756

RESUMO

PURPOSE: The purpose of this study was to calibrate and evaluate the precision of the new applanation resonance tonometry (ART) in a clinical study designed in accordance with the International Standard Organization's requirements. METHODS: This was a prospective, randomized, single-center study, where healthy volunteers and patients participated. A total of 153 eyes were divided into 3 groups with respect to their intraocular pressure (IOP) at screening: <16 mm Hg, 16 to 23 mm Hg, and >23 mm Hg. IOP was measured with Goldmann applanation tonometry (GAT) as reference method and by ART in both a biomicroscope (ARTBiom) and a handheld (ARTHand) setup with a 10-minutes pause between methods. The mean of 6 readings was regarded as one measurement value. RESULTS: Mean age of the subjects was 59 years (range 20 to 87 y). GAT showed a mean IOP of 20.0 mm Hg (range 8.5 to 43.5 mm Hg, n=153). The precision was 2.07 mm Hg for ARTBiom and 2.50 mm Hg for ARTHand, with a significant dependency for age as compared with GAT. Measurement order produced a decreasing IOP with a mean of 2.3 mm Hg between the first and last method. CONCLUSIONS: The precision obtained in both ARTBiom and ARTHand was within the limits set by the International Standard Organization standards for tonometers. The standardized procedure and the stability of the biomicroscope setup resulted in a slightly better precision as compared with the handheld setup. Despite a 10-minutes pause between measurements, the order was a significant factor, possibly because the patients were more apprehensive at the first measurement.


Assuntos
Glaucoma/diagnóstico , Pressão Intraocular , Tonometria Ocular/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Calibragem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Tonometria Ocular/instrumentação , Tonometria Ocular/normas
19.
Med Biol Eng Comput ; 44(1-2): 54-60, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16929921

RESUMO

Applanation resonance tonometry (ART) has been shown in a number of studies to be useful for measuring intraocular pressure (IOP). Data from in vitro laboratory bench testing, where the sensor was carefully centralised onto the cornea, has been very consistent with good precision in the determination of IOP. However, in a clinical study the unavoidable off-centre placement of the sensor against the cornea resulted in a reduced precision. The aim of this study was to evaluate a new design of the sensor with a symmetric sensor probe and a contact piece with a larger diameter. Two in vitro porcine eye experimental set-ups were used. One bench-based for examining position dependence and one biomicroscope-based set-up, simulating a clinical setting, for evaluating IOP(ART) precision at seven different pressure levels (1040 mmHg), set by connecting a saline column to the vitreous chamber. The reference IOP was recorded using a pressure transducer. There was no significant difference between four positions 1 mm off centre and the one centre position. The precision of the ART as compared with the reference pressure was +/- 1.03 mmHg (SD, n = 42). The design improvement has enhanced the precision of the ART in the biomicroscope set-up to be in parity with bench test results from a set-up using perfect positioning. This indicates that off-centre positioning was no longer a major contributor to the deviations in measured IOP. The precision was well within the limits set by ISO standard for eye tonometers. Therefore, a larger in vivo study on human eyes with the ART should be performed.


Assuntos
Pressão Intraocular , Tonometria Ocular/métodos , Animais , Calibragem , Desenho de Equipamento , Glaucoma/diagnóstico , Modelos Animais , Suínos , Tonometria Ocular/instrumentação , Transdutores
20.
Med Biol Eng Comput ; 44(8): 609-18, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16937203

RESUMO

Excimer laser surgery, to correct corneal refraction, induces changes in corneal thickness and curvature. Both factors can cause measurement errors when determining intraocular pressure (IOP). This study evaluates effects of photorefractive keratectomy (PRK) on IOP measurements, using Goldmann applanation tonometry (GAT) and Applanation resonance tonometry (ART), in an in vitro model. Six porcine eyes was enucleated and pressurised to a constant IOP=30 mmHg. After removal of the epithelium, the eyes were PRK-treated for a total of 25 dioptres. The measured IOP decreased 13.2 mmHg for GAT and 9.0 mmHg for ART. The total underestimation by GAT was larger than for ART, and a part of the ART underestimation (3.5 mmHg) was assigned to sensitivity to the change in corneal surface structure resulting from the removal of epithelium. The flat contact probe of GAT, as compared with the convex tip of ART, provided explanation for the difference in IOP measurement error after PRK.


Assuntos
Pressão Intraocular/fisiologia , Ceratectomia Fotorrefrativa , Animais , Fenômenos Biomecânicos , Cadáver , Lasers de Excimer , Matemática , Modelos Animais , Refração Ocular/fisiologia , Tonometria Ocular/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...